Wholesale Medical Plasma Sterilizer H2o2 Plasma Sterilizer Medical Low Temperature Plasma Sterilizer Manufacturer, Service

Product Description

Cost-Effective
Fast and Efficient
Average cycle length 32 min
Simple installation
Large Capacity
Automatic Door-Pedal Operator
For hands-free use
User-Friendly Touch Screen Display
USB interface
Technical Parameters
Model
YJ-PVS130
External Dimensions
1060 (L) × 860 (W) × 1660 (H)
Chamber Dimensions
432 (L) × 790 (W) × 420 (H)
Weight
470 kg
Chamber Capacity
130 L
Control Interface
Touch screen (7-inch LCD)
External Temperature
5°C–40°C
Humidity
30%–80%
Rated Input
AC220V/50Hz
Rated Power
3.6 kW
Internal Temperature
40°C–55°C
Cycle Period
30–60 min
Remarks: All specifications can be altered to suit the clients’ needs.
Product Description
The latest technology, excellent performance. Rapid sterilization cycle, energy efficient, easy to install, safe for staff to use and friendly to the environment.
YJ-PVS130 sterilizer
NO
Name
Function
1
Sterilization Bin
Loading medical devices that require sterilization
2
Printer Room
Built-in printer, which can automatically print sterilization process information
3
LED Indicator
Indication of sterilizer status, operation, failure, standby
4
Display
7-inch display, operation interface
5
Hydrogen Peroxide Chamber
Reproduced hydrogen peroxide sterilizer
6
Foot Switch
The sterilization compartment door can be opened and closed through the sensing foot
7
Main Power Switch
Main power switch of the sterilizer
8
Exhaust Fan
Dissipating heat from the sterilizer during sterilization
FAQ
What is the model and external dimensions?
Model YJ-PVS130. External dimensions: 1060 (L) × 860 (W) × 1660 (H).
What are the chamber dimensions and chamber capacity?
Chamber dimensions: 432 (L) × 790 (W) × 420 (H). Chamber capacity: 130 L.
How long does a sterilization cycle take?
The cycle period is 30–60 minutes. The stated average cycle length is 32 minutes.
What control and documentation features does the sterilizer have?
It has a user-friendly 7-inch LCD touch screen and USB interface. It also includes a built-in printer that can automatically print sterilization process information and an LED indicator for operation, failure, and standby status.
How is the sterilizer door operated?
The automatic door-pedal operator supports hands-free use. A foot switch allows the sterilization compartment door to be opened and closed through foot sensing.
What are the power, temperature, and humidity requirements?
Rated input is AC220V/50Hz and rated power is 3.6 kW. External temperature is 5°C–40°C, humidity is 30%–80%, and internal temperature is 40°C–55°C.