Package Dimensions ‏
11.8 x 11.6 x 10.6 inches
Voltage
AC110V 60 HZ
Capacity
20ml×6
Centrifugal Capacity
20ml per tube
Max Speed
4000r/min

Product Description

Electric Centrifuge Machine – Desktop Laboratory Benchtop Centrifuge with Timer and Speed Control for Lab & Medical Practice
Electric centrifuge machine with timer and speed control
Adjustable Time and Speed
The two rotary switches of the lab benchtop centrifuge control speed and time independently. Speed range: 0–4,000 r/min; time range: 0–60 minutes; maximum relative centrifugal force: 1,790 × g; power supply: AC110V, 60 Hz.
High-Efficiency 20 mL × 6 Rotor
This laboratory centrifuge provides 6 tubes, and each tube has a 20 mL centrifugation capacity, helping improve workflow efficiency. Note: tubes must be inserted into the machine symmetrically; asymmetrical operation is not allowed.
Wide Range of Applications
This desktop centrifuge is widely used in laboratories and production departments such as chemistry. It is a practical benchtop companion for mobile workflows and is also suitable for making small-batch cocktails at home. It can be used for algae sample dehydration, PRP, beauty applications, and more.
Specifications
Package Dimensions
11.8 x 11.6 x 10.6 inches
Voltage
AC110V 60 Hz
Capacity
20 mL × 6
Centrifugal Capacity
20 mL per tube
Max Speed
4,000 r/min
Time Range
0–60 min
Max Relative Centrifugal Force
1,790 × g
Ambient Temperature
0–30°C
Relative Humidity
<80%
Details
Frequently Asked Questions
What speed and time settings are available?
The centrifuge offers a speed range of 0–4,000 r/min and a time range of 0–60 minutes. Its maximum relative centrifugal force is 1,790 × g.
How many tubes can this centrifuge hold?
It has a 20 mL × 6 rotor and holds six tubes, with a 20 mL centrifugation capacity per tube.
What power supply does the machine require?
The machine operates on AC110V, 60 Hz.
How should the tubes be loaded?
Tubes must be inserted into the machine symmetrically. Asymmetrical operation of the machine is not allowed.
What are the recommended operating conditions?
The ambient temperature should be 0–30°C, and the relative humidity should be below 80%.
What applications is this laboratory centrifuge suitable for?
It is suitable for laboratories, production departments such as chemistry, algae sample dehydration, PRP, beauty applications, small-batch cocktail preparation at home, and other related uses.