ODM Multiparameter Defibrillator Monitor Emergency Cardiac Arrest Response Device Plastic Metal Construction Electricity Machinery Manufacturer, Manufacturers

Product Description

Defibrillator monitor device
Key Features & Specifications
1
Built-in Recorder
Standard built-in recorder; defibrillation discharge trigger recording.
2
Li-ion Battery
Standard Li-ion battery.
3
TFT Colour Display
Screen size: 7 inches (17.7 cm) diagonally.
4
ECG
3-lead ECG cable, or 5-lead ECG cable, paddles.
Displayed on monitor, paddles, I, II, III, aVR, aVL, aVF, V.
5
NIBP
Method: automatic oscillation.
Working mode: manual/automatic.
6
TEMP
Measurement range: 20–45 ℃.
7
SpO2
Display: SpO2 value, pulse histogram, waveform, pulse.
8
Pulse
Pulse range: 0–300 bpm.
Pulse accuracy: ±2 bpm.
9
Defibrillator
Biphasic / Manual External Synchronous / Asynchronous Defibrillation.
Charge Time: Less than 10 seconds to 360 Joules.
Energy Selection: Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules.
Standard Adult / Pediatric Paddles: Reusable external adult paddles (pediatric paddles integrated).
10
AED Optional
Adult Mode: 150J / 150J / 200J; 120J / 120J / 150J.
Children Mode: 50J / 50J / 75J; 30J / 30J / 50J.
Standard & Optional Configuration
Standard
Biphasic defibrillation / ECG / NIBP / TEMP / SpO2 / Pulse / Print / Li-ion Battery
Optional
AED & PACER
Frequently Asked Questions
What defibrillation modes does the device support?
It supports biphasic defibrillation and manual external synchronous/asynchronous defibrillation. AED and pacer are available as optional functions.
What is the maximum charge time and available energy levels?
The charge time is less than 10 seconds to 360 Joules. Energy selection includes 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, and 360 joules.
Which monitoring parameters are included?
ECG, NIBP, temperature, SpO2, and pulse are included, along with a built-in recorder and standard Li-ion battery. Printing is listed as standard.
What ECG leads and display views are supported?
It accepts a 3-lead ECG cable or 5-lead ECG cable, or paddles. Display views include monitor, paddles, I, II, III, aVR, aVL, aVF, and V.
What are the NIBP and temperature measurement specifications?
NIBP uses the automatic oscillation method and supports manual/automatic working modes. The temperature measurement range is 20–45 ℃.
What are the screen, pulse, and AED energy specifications?
The screen is a 7-inch TFT colour display. Pulse range is 0–300 bpm with ±2 bpm accuracy. In optional AED mode, adult energy sequences are 150J/150J/200J and 120J/120J/150J; children mode sequences are 50J/50J/75J and 30J/30J/50J.