China Cheap Price Portable Adult Neonatal Children Cardiac Monitor Multi Parameters Vital Signs Patient Monitor Manufacturer, Factory

Product Description

Multi-parameter patient monitor for vital signs monitoring
Feature
1
12.1" TFT color LCD, 800 × 600 dpi.
2
Standard 5-parameter monitoring: ECG, SpO2, NIBP, TEMP, and RESP.
3
Fanless design: quiet, energy-saving, and clean.
4
Standard interface, OxyCRG, trend chart, large-character interface, and view bed.
5
Operation mode: keys and buttons.
6
Displays up to 8-channel waveforms on one screen.
7
NIBP measurement modes: Manual / AUTO / Continuous; storage for 1000 groups of NIBP data.
8
Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9
Drug concentration calculation and titration table functions.
10
One-key printing of trend table data.
11
Connects to the Central Monitoring System in Wi-Fi or wired mode.
12
AC/DC operation and a built-in rechargeable lithium battery achieve uninterrupted monitoring.
13
Anti-high-frequency surgical unit and defibrillation-proof (special leads are necessary).
Technical Specification
ECG
Lead mode
3/5-lead (R, L, F, N, C)
Lead selection
I, II, III, aVR, aVL, aVF, V
Waveform
3- and 7-channel selectable
Gain selection
0.5 mm/mV, 1 mm/mV, 2 mm/mV
Sweep speed
12.5 mm/s, 25 mm/s, 50 mm/s
Heart rate range
Adult: 15–300 bpm; neonate/pediatric: 15–350 bpm
Accuracy
±1 bpm or ±1%, whichever is greater
Resolution
1 bpm
Filter
Surgery mode: 1–20 Hz; monitor mode: 0.5–40 Hz; diagnostic mode: 0.05–130 Hz
Scaling signal
1 mV, ±3%
Protection
Withstands 4000 VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range
15–350 bpm
S-T measurement range
−2.0 mV to +2.0 mV
S-T alarm range
−2.0 mV to +2.0 mV
S-T accuracy
−0.8 mV to +0.8 mV ±0.02 mV
Arrhythmia analysis
Yes
SpO2
Measurement range
0–100%
Resolution
1%
Accuracy
±2% (70–100%); 0–69% unspecified
Alarm range
0–100%
Pulse rate range
20–300 bpm
Pulse rate resolution
1 bpm
Error
±1 bpm or ±2%, whichever is greater
NIBP
Method
Digital automatic oscillometric
Operation mode
Manual / Automatic / Continuous
Auto measurement time
Adjustable (1–480 min)
Measurement unit
mmHg / kPa selectable
Measurement types
Systolic, Diastolic, Mean
Systolic pressure range
Adult 40–270 mmHg; pediatric 40–220 mmHg; neonate 40–135 mmHg
Mean pressure range
Adult 20–235 mmHg; pediatric 20–165 mmHg; neonate 20–110 mmHg
Diastolic pressure range
Adult 10–215 mmHg; pediatric 10–150 mmHg; neonate 10–100 mmHg
Over-pressure protection
Double safety protection
Resolution
1 mmHg
Alarm
Systolic, Diastolic, Mean
RESPIRATION
Method
Thoracic impedance
Measurement range
Adult 7–120 rpm; neonate/pediatric 7–150 rpm
Apnea alarm
Yes, 10–40 s
Resolution
1 rpm
Accuracy
±2 rpm
TEMP
Compatible probe
YSI or CYF
Measurement range
5–50°C
Resolution
0.1°C
Accuracy
±0.1°C
Refreshing time
About 1 s
Average measuring time
<10 s
FAQ
What type of display does the multi-parameter patient monitor have?
It has a 12.1" TFT color LCD with 800 × 600 dpi.
Which vital signs can be monitored?
It supports standard 5-parameter monitoring: ECG, SpO2, NIBP, TEMP, and RESP.
Can the monitor continue working during power interruptions?
It supports AC/DC operation and has a built-in rechargeable lithium battery for uninterrupted monitoring.
What NIBP measurement modes are available?
Manual, automatic, and continuous modes are available; auto measurement time is adjustable from 1 to 480 minutes.
How can the monitor connect to a central monitoring system?
It can connect to the Central Monitoring System in Wi-Fi or wired mode.
Does this patient monitor support arrhythmia analysis?
Yes. It provides arrhythmia analysis and can review up to 60 arrhythmia alarm events.