Multi Parameter Patient Monitor Price Patient Vital Signs Monitor
1
12.1" TFT color LCD, 800 × 600
2
Standard 5 parameters: ECG, SpO2, NIBP, TEMP, RESP
3
Fanless design, quiet, energy-saving and clean.
4
With standard interface, OxyCRG, trend chart, big character interface and view bed.
5
Operation mode: keys and buttons.
6
Display up to 8-channel waveform on one screen.
7
NIBP measurement mode: Manual/AUTO/Continuous; storage for 1000-group NIBP data.
8
Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9
Drug concentration calculation and titration table functions.
10
Print trend table data with one-key.
11
Connect to Central Monitoring System via WiFi or wired mode.
12
AC/DC; built-in rechargeable lithium battery achieves uninterrupted monitoring.
13
Anti-high-frequency surgical unit; defibrillation-proof (special leads are necessary).
⚙
Technical Specifications
ECG
Lead mode
3/5-lead (R, L, F, N, C)
Lead selection
I, II, III, aVR, aVL, aVF, V
Waveform
3 and 7-channel selectable
Gain selection
0.5 mm/mV, 1 mm/mV, 2 mm/mV
Sweep speed
12.5 mm/s, 25 mm/s, 50 mm/s
Heart rate range
Adult: 15–300 bpm; Neonate/pediatric: 15–350 bpm
Accuracy
±1 bpm or ±1%, whichever is greater
Filter
Surgery mode: 1–20 Hz
Monitor mode: 0.5–40 Hz
Diagnostic mode: 0.05–130 Hz
Protection
Withstand 4000 VAC/50 voltage isolation against electrosurgical interference and defibrillation
S-T segment detection
Measurement range: -2.0 mV to +2.0 mV
Alarm range: -2.0 mV to +2.0 mV
Accuracy: -0.8 mV to +0.8 mV, ±0.02 mV
SpO2
Accuracy
±2% (70–100%); 0–69% unspecified
Pulse rate range
20–300 bpm
Pulse rate resolution
1 bpm
Pulse rate error
±1 bpm or ±2%, whichever is greater
NIBP
Method
Digital automatic oscillometric
Operation mode
Manual/Automatic/Continuous
Auto measurement time
Adjustable (1–480 min)
Measurement unit
mmHg/kPa selectable
Measurement types
Systolic, Diastolic, Mean
Systolic pressure range
Adult: 40–270 mmHg
Pediatric: 40–220 mmHg
Neonate: 40–135 mmHg
Mean pressure range
Adult: 20–235 mmHg
Pediatric: 20–165 mmHg
Neonate: 20–110 mmHg
Diastolic pressure range
Adult: 10–215 mmHg
Pediatric: 10–150 mmHg
Neonate: 10–100 mmHg
Over-pressure protection
Double safety protection
Alarm
Systolic, Diastolic, Mean
Respiration
Method
Thoracic impedance
Measurement range
Adult: 7–120 rpm; Neonate/pediatric: 7–150 rpm
TEMP
Compatible probe
YSI or CYF
Refreshing time
About 1 s
Average measuring time
<10 s
Q
What parameters can this patient monitor measure?
It supports standard 5 parameters: ECG, SpO2, NIBP, TEMP and RESP.
Q
What is the display and waveform capability?
It uses a 12.1" TFT color LCD with 800 × 600 resolution and can display up to 8-channel waveform on one screen.
Q
What NIBP measurement modes are available?
NIBP supports manual, automatic and continuous modes, with storage for 1000-group NIBP data.
Q
Can this monitor connect to a central monitoring system?
Yes. It can connect to the Central Monitoring System via WiFi or wired mode.
Q
Does it support uninterrupted monitoring with a battery?
Yes. AC/DC operation and a built-in rechargeable lithium battery achieve uninterrupted monitoring.
Q
What alarm and protection features are available?
It supports review of 71 alarm events for all parameters and 60 arrhythmia alarm events. It also has anti-high-frequency surgical unit and defibrillation-proof protection; special leads are necessary.